- High-side voltage
- 115 kV
- Low-side voltage
- 13.8 kV
- Listed quantity
- 2 — individually or as a pair
Review power-transformer and mobile-substation candidates for utility, campus and industrial substation requirements. These are catalog candidates for engineering review, not a claim that every listed unit is approved for every substation duty.
60 catalog listings · 38 new/unused · 20 pre-owned
Submit your specifications| Capacity range | 5–400 MVA based on each listing’s maximum stated rating. Full ratings and cooling conditions govern usable capacity. |
|---|---|
| Low-side options in this collection | 12.47 kV, 12.47 or 24.94 kV, 13.2 kV, 13.8 kV, 14.4 kV, 21.6 kV, 24.9 kV, 24.94 kV, 33 kV, 34 kV, 34.5 kV, 36.3 kV, 4.16 kV, 4.16/2.4 kV, 69 kV, 7200/12470Y/7200 V. Multiple options do not establish simultaneous windings. |
| Availability | Subject to prior sale and written confirmation. Listing counts are not unit quantities; no dispatch date is guaranteed by catalog inclusion. |
Send the required continuous rating, cooling stages, primary and secondary voltages, taps and installation constraints. This collection also contains larger units; a displayed maximum rating is not the base rating. A transformer listing is not a complete substation package unless the quotation expressly includes the other equipment and services.
Use the nameplate guide and quote-comparison guide when reviewing candidates.















Compare terminal locations, clearances, grounding, protection interfaces, auxiliary power and footprint against the site design. Confirm whether the inquiry concerns a transformer alone or a complete mobile substation; included breakers, controls and other equipment must be itemized.
For new/unused equipment, confirm storage and preservation, factory records, completeness and any transferable warranty. For pre-owned equipment, request operating and maintenance history, removal details, oil and electrical testing, and documented repairs. A catalog condition label does not establish a remaining service life or test result.
Ask for the nameplate, winding diagram, general arrangement, available tests, accessory list, shipping configuration, weights and oil information. List missing records and proposed inspections in the purchase review.
Read the related procurement guideConfirm origin and destination, site access, preparation, oil handling, accessory shipments, transport permits, offloading and installation scope. Agree whether a quoted date means factory release, pickup, site arrival or readiness for commissioning.
Discuss turnkey delivery and installationContact Transformer Traders using the equipment ID from this collection or submit your specification. We review published inventory and additional sourcing opportunities, with price, availability and scope confirmed in writing.
Catalog availability is not a dispatch commitment. Document review, inspection, preparation, loading, permits and receiving-site readiness determine the delivery plan for the individual unit.
Send the mandatory ratings, winding voltages, physical constraints, quantity and deadline. We can review other surplus and pre-owned sources or discuss a new-build option. Engineering acceptance remains project-specific.
New & unused inventory · Used & pre-owned inventory · Documentation checklist · New-build options
Include an equipment ID or your required MVA, voltages, quantity, location and delivery date.